Input Power | |
Input Rating | 230 VAC, single phase 16A, 50/60Hz per Gun |
Number of Phase / Wire | L, N and PE (Ground), hardwired with terminal block |
Standby Power | <15W |
Output Power | |
Output Rating | 230 VAC, single phase 16A, 50/60Hz per Gun |
Charging Interface | 3.5 kW x 2Gun (IEC 62196-2) |
Protection | |
Upstream | In accordance with local regulations |
Electrical Protection | Over current, Under voltage, Over voltage, Residual current, Surge protection, Short circuit, Over temperature, Ground fault, Plug-out protection, Emergency Stop |
Automatic recovery after Nuisance Trip | The EVSE will automatically resume charging after a minor fault such as OVP, UVP, OTP or OCP. No user intervention required. |
User Interface & Control | |
Status Indicators | Power, Status, Charge, Fault |
Buttons and Switch | Key switch, On/Off switch, Reset button |
Charger Configuration | Charging Current Adjustment, Charging Duration Limitation using Remote Application |
Communication | |
Network Interface | LTE CAT1 Network, (Optional - Ethernet/ Bluetooth/ WIFI/ RFID) |
Charging Protocol | MQTT, OCPP 1.6 |
Mechanical | |
Mechanical | Can be customized as per Customer Requirement |
Dimension (WxHxD) / Weight | 300 x 500 x 120 mm, excluding charging cable, mounting plate and cable holder, 6kg(approx.) without package |
Regulation | |
Certificate / Compliance | Our Product is in compliance as per ARAI Standard |